EW 1

 Banner-product-EW-1

 

Highest flexibility is granted by the compact design, which assures low cycle costs by reduced consumption of water, chemicals and energy.

The integrated monitoring system assures a higher level of safety by checking flow and pressure of the instrument connection. Steelco EW 1 endoscope reprocessor is endowed with a stainless steel base for the storage of process chemicals. Free standing or table top - the EW 1 design provides an installation set for any facility.

Banner-product-EW-1-rackUsing the “rackoption, two or four EW 1 machines will be installed on the top of each other on a mobile shelf. This set up allows asynchronous reprocessing of 2 or 4 flexible endoscopes on a small footprint. Furthermore, available the pass-through version!

Process traceability made easy
Instrument and operator recognition can be faster through the bar-code reader option. Batch data information can be stored on a memory stick connected to the integrated USB interface.

Optimal performance with Steelco chemicals
By using Steelco process chemicals the EW 1 automatic endoscope reprocessor reaches the highest efficiency results proven by microbiological tests together with complete documentation and instruments maximum safety conditions.

Banner-product-chemicals-ABDT

 

What is the level of treatment required for your endoscopes?
Now you have the freedom to choose the most suitable and safe process!

DOUBLE ISO 15883-4 & ISO 14937 COMBINATION COMPLIANCE

 

 

Banner-product-EW-1-disinfectedEW 1 system is  also compliant to ISO 15883-4 with fast validated High Level Disinfection cycles that allow a fast endoscopes turnover in busy Departments.
Banner-product-EW-1-sterilizedEW 1 technology has been validated according to ISO 14937 - as a Liquid Sterilizer - in line with customers needs and endoscope reprocessing latest requirements to fulfill Pneumology, Urology and Gastroenterology Departments requests of higher standard of logarithmic reduction.

 

 This functionality depends to the registration in the country of destinations of the chemicals Steelco Xide A, B, DT.

 

  •  

    Dimensions WxDxH mm (inches):
    EW 1 single door
    stand alone: 600 x 630 x 960 (23.62 x 24.80 x 36.22)
    rack version: 750 x 690 x 1643 (29.53 x 27.16 x 64.68)
    EW 1 double door
    stand alone: 710 x 570 x 1206 (27.95 x 22.44 x 47.48)
    rack version: 860 x 570 x 1663 (33.86 x 22.44 x 65.47)

    • 3 level service menu, protected by password (installation, service, user)
    • Integrated endoscope channel monitoring system with 2 independent sensors
    • Leak test at the beginning of the cycle and continuous monitoring during all cycle phases with automatic cycle stop in case of anomaly
    • Control panel “soft touch” with LCD color display with highlight of remaining time to cycle completion
    • Process documentation by external printer or USB interface
    • Thermal self disinfection cycle of the washer and of the washing basket according to EN ISO 15883-4
    • Safe and easy chemical operation
    • Microbiological filtration

    Not available for sales USA market.

  •  

    2_EW 1, dedicated catalogue